Article 4.4.6.2.2.

1.

All systems measured must be counted and documented in a convenient and verifiable manner (for example, by process flow diagram) according to the types stated in Chapter III of Appendix 4.4.6. These counts are to be included in the inventory.

2.

If the measurement value for the system measured exceeds the registration criterion, the following information must be added to the inventory or updated within two months of the measurement:

1

identification of the system: type, location, identification number;

2

name of product;

3

description of the product flow:

a)

gaseous or liquid;

b)

percent by weight of organic compounds (excluding methane; percent by volume in the case of gasses) at a vapour pressure in excess of 0.3 kPa at 20C;

4

date and results of measurements taken;

5

repairs made and date and result of control measurements.